Helium leak testing equipment for Cast resin components |

Double chamber system
- Two-sided testing
- Helium concentration optionally 50 – 100 %
- Type-specific tool pickup
- Manual fitting
- Automatic testing sequence
- Optical „Go/No-go“ indicator
Technical details:
Cycle time 45 sec. Leak rate 1.0 · 10-6 mbarl/s Test pressure 1.5 bar abs. 0 bar Helium concentration 50 - 100 % He

|
|
Helium leak testing equipment for sf6 voltage switches |

- Automatic SF6 charging
- Helium recovery
- Vacuum chamber from 1.4301
- Process visualization WinCC
- Data archiving of readings
- Logger
- Gross weight: 10 t
- Dimensions: L = 10 m D = 6 m H = 4 m
Technical details:
Chamber size 7.5 m3 Pumping speed 5000 m3/h Cycle time 10 min. Leak rate 1.0 · 10-6 mbarl/s Test pressure 1.5 bar abs. 0 bar Helium concentration 100 % He

|
SF6 leak testing system for SF6 compressed air feed pipes |

- Mobile system
- Automatic sequence
- Integral vacuum leak test in accordance with the carrier gas principle
- Vacuum bell accommodates every position on test piece
Technical details:
Cycle time 45 sec. Leak rate 1.0 · 10-6 mbarl/s Test pressure 1.5 bar abs. 0.4 bar SF6 concentration 100% SF6

|
|
|
|
|